Skip to product information
1 of 2

Gold Cura

Gold Cura Sterilization Reels | Heat-Seal Autoclave Pouch Rolls for Dental Clinics

Regular price Rs. 650.00 INR
Regular price Sale price Rs. 650.00 INR
Taxes included. Shipping calculated at checkout.

Low stock

Size
Quantity
Pan-India deliveryTimelines depend on stock, product and pincode.
Product-specific supportCompatibility, setup and warranty assistance where applicable.

Sterilization Reels for Dental Instrument Packaging

Gold Cura Sterilization Reels are cut-to-size paper-and-transparent-film pouch rolls designed for packaging reusable dental instruments before sterilization.

Important: These reels are not self-sealing. After cutting the required pouch length, both open ends must be securely closed using a compatible heat-sealing machine.

Each 200-metre roll allows dental clinics to prepare pouches according to the length of their instruments, helping reduce wastage compared with using only fixed-size sterilization pouches.

The transparent film makes the packaged instruments easy to identify, while the paper side allows penetration of the sterilizing agent during a compatible sterilization cycle. Once correctly heat-sealed, processed, dried and stored, the packaging helps protect instruments from contamination until the pouch is opened for use.

Available Sizes

Choose the reel width according to the instruments being packed:

  • 55 mm × 200 m
  • 75 mm × 200 m
  • 100 mm × 200 m

All three variants contain a 200-metre-long roll.

Key Features

  • Cut-to-size sterilization pouch roll
  • Not self-sealing—requires a compatible heat-sealing machine
  • Available in 55 mm, 75 mm and 100 mm widths
  • 200-metre roll for regular clinic requirements
  • Paper-and-transparent-film construction
  • Transparent side helps identify instruments without opening the pouch
  • Allows customized pouch lengths for different dental instruments
  • Printed process indicators help distinguish processed packs from unprocessed packs
  • Designed for dental clinics, hospitals, laboratories and sterilization areas
  • Helps protect properly processed instruments during handling and storage

Product Specifications

Specification Details
Product Sterilization Reel
Brand Gold Cura
Available widths 55 mm, 75 mm and 100 mm
Roll length 200 metres
Construction Paper and transparent film
Closure method Heat sealing with a compatible sealing machine
Self-sealing No
Usage Cut-to-size instrument packaging
Application Packaging instruments before sterilization
Intended users Dental and healthcare professionals
Reusability Single-use packaging
Sealing machine required Yes

How to Select the Correct Width

55 mm Reel

Suitable for narrow instruments and small individual items that fit comfortably within the pouch without stressing the seals.

75 mm Reel

Suitable for many commonly used dental hand instruments and small instrument combinations.

100 mm Reel

Suitable for wider instruments, instrument sets or items that require additional space within the pouch.

Always select a reel wide enough to accommodate the instrument without forcing it against the paper, film or sealed edges.

How to Use — Sealing Machine Required

  1. Clean, rinse and thoroughly dry the reusable instruments before packaging.
  2. Select the appropriate reel width for the instrument.
  3. Cut the reel to the required length, leaving sufficient extra space at both ends for proper sealing.
  4. Place one open end into a compatible heat-sealing machine and create a complete, even seal.
  5. Allow the first seal to cool briefly, then place the clean and dry instrument inside without overfilling the pouch.
  6. Add an appropriate internal chemical indicator when required by the clinic’s sterilization protocol.
  7. Place the remaining open end into the sealing machine and heat-seal it completely.
  8. Inspect both seals. They should be continuous, even and free from gaps, folds, wrinkles or burns.
  9. Label the pouch according to the clinic’s instrument-processing protocol.
  10. Process the sealed pouch using a compatible sterilization cycle and follow the instructions supplied with the sterilizer, instrument, sealing machine and packaging material.
  11. Allow the pouch to cool and dry completely before handling or storage.
  12. Inspect the pouch, both heat seals and the process indicators before storing or opening it for clinical use.

Do not attempt to use the reel without sealing both ends with a suitable sealing machine.

Important Information About Sterilization Indicators

The printed chemical indicators help show that the pouch has been exposed to specified sterilization-process conditions.

A colour change does not independently confirm sterility and does not replace:

  • Internal chemical indicators
  • Mechanical cycle monitoring
  • Periodic biological or spore testing
  • Proper cleaning and drying of instruments
  • Correct sterilizer loading
  • Following the sterilizer manufacturer’s instructions

Do not use instruments from a pack when the required indicator change has not occurred or when the sterilization cycle has failed.

Packaging and Storage Instructions

  • Package only instruments that have been properly cleaned and completely dried.
  • Use a compatible sealing machine and follow its recommended operating settings.
  • Do not overfill the pouch.
  • Keep instruments away from the heat-sealed edges.
  • Do not use a pouch with an incomplete, wrinkled, burnt, open or damaged seal.
  • Allow processed packs to cool and dry before handling.
  • Store processed instruments in a clean, dry and covered area.
  • Inspect every pouch before use.
  • Reprocess the instruments when the pouch is wet, torn, punctured, opened or otherwise compromised.
  • Do not reuse the packaging material.

Suitable Applications

Gold Cura Sterilization Reels can be used for packaging compatible reusable items such as:

  • Dental diagnostic instruments
  • Hand instruments
  • Endodontic instruments
  • Periodontal instruments
  • Restorative instruments
  • Orthodontic instruments
  • Small surgical instruments
  • Individual dental accessories that are suitable for sterilization

The instrument, pouch material and selected sterilization process must be mutually compatible.

Frequently Asked Questions

What is a sterilization reel used for?

A sterilization reel is used to create customized paper-and-film pouches for packaging cleaned dental instruments before sterilization.

Which sizes are available?

Gold Cura Sterilization Reels are available in:

  • 55 mm × 200 m
  • 75 mm × 200 m
  • 100 mm × 200 m

Is this a self-sealing sterilization reel?

No. This product is not self-sealing and does not include an adhesive closure. After cutting the required pouch length, both open ends must be securely heat-sealed using a compatible sealing machine.

Do I need a sealing machine?

Yes. A compatible heat-sealing machine is required to create secure seals at both ends of the pouch before sterilization.

Can I close the pouch manually or with adhesive tape?

No. The reel should be closed using a compatible sealing machine. Manual folding, ordinary adhesive tape or an incomplete seal may not provide suitable package integrity.

How are both ends sealed?

First cut the required length and heat-seal one end. Insert the clean and dry instrument, then use the sealing machine again to close the remaining open end. Inspect both seals before sterilization.

Does the indicator prove that the instruments are sterile?

No. The printed process indicator shows exposure to specified sterilization conditions. It does not independently prove sterility or replace the clinic’s complete sterilization-monitoring process.

Can the reel be cut according to the instrument length?

Yes. The continuous 200-metre format allows the user to prepare pouch lengths according to the instruments being packaged.

Can the pouches be reused?

No. The cut and heat-sealed packaging is intended for single use only.

Can wet instruments be placed inside?

No. Instruments should be thoroughly cleaned and dried before packaging. Moisture can affect the integrity of the pouch and the sterilization process.

When should a processed pouch be rejected?

Do not use the contents when the pouch is wet, torn, punctured, improperly sealed, opened or otherwise damaged. The instruments should be cleaned, repackaged in a new pouch and processed again according to the clinic’s protocol.

Browse related products: Dental Sterilization Supplies & Infection Control.

View full details